Characteristics
● Special composite material loose casing to reduce low temperature casing retraction.
● Precise control of fiber residual length, stable performance of optical cable.
●Unique process control to eliminate sheath wrinkling in air blowing.
●High density polyethylene outer sheath to improve air blowing distance.
Standards
IEC 60794-5、IEC 60794-1-2 or D/T 1460-2006
Optical Characteristics
G.652 | G.655 | 50/125μm | 62.5/125μm | ||
Attenuation (+20℃) | @850nm | ≤3.0dB/km | ≤3.0dB/km | ||
@1300nm | ≤1.0dB/km | ≤1.0dB/km | |||
@1310nm | ≤0.36dB/km | ≤0.36dB/km | |||
@1550nm | ≤0.22dB/km | ≤0.23dB/km | |||
Bandwidth (Class A) | @850 | ≥500MHZ·km | ≥200MHZ·km | ||
@1300 | ≥1000MHZ·km | ≥600MHZ·km | |||
Numerical Aperture | 0.200±0.015NA | 0.275±0.015NA | |||
Cable Cut-off Wavelength λcc | ≤1260nm | ≤1480nm |
Technical Parameters
Mini Cable Type | GCYFXY-xxF(MTE +Outer diameter) | ||||
MTE1.8 | MTE2.0 | MTE2.3 | MTE2.5 | MTE2.8 | |
Fiber Count | 2~4 | 2~4 | 6~12 | 2~12 | 14~24 |
HDPE Outer Sheath Thickness | Nominal:0.20mm,Mini: 0.15mm | ||||
Nominal Outer Diameter | 1.8mm | 2.0mm | 2.3mm | 2.5mm | 2.8mm |
Approximate Weight | 2.6 kg/km | 4.0 kg/km | 5.0 kg/km | 6.0 kg/km | 7.0kg/km |
Attenuation (single-mode fiber) | 1310nm/1550nm≤0.35/0.22dB/km | ||||
Max. Pulling Force | 40N | 40N | 50N | 60N | 60N |
Max. Squeeze Force | 600N/100mm | ||||
Mini Permissible Static / Dynamic Bending Radius | 10x/20x O.D. of fiber optic cable | ||||
Temperature Range | Storage -30~+60℃; Installation -10~+40℃; Operation -20~+50℃ | ||||
Fiber optic cable life (valuation) | 25 YEARS |
Mechanical performance
Items | Test Reference Standards | Test Results | Remarks | ||
Tension | IEC 60794-1-2-E1 (GB/T 7424.2-E1) | Fiber Strain(%) | Accessory Decay(dB) | Short-term test tension is the maximum tension.Long-term test tension is 1/3 of the maximum tension | |
Short-term ≤0.3 Long-term ≤0.1 | Short-term:≤0.1, No significant strain after stress relief; Long-term:No Significant | ||||
Flattening force | IEC 60794-1-2-E3 (GB/T 7424.2-E3) | Short-term crushing force: additional attenuation ≤ 0.05.Long-term crushing force: no significant.After stress removal, no visible residual additional attenuation of the fiber, the No visible cracking on the sheath surface | Short-term test pressure:600NLong-term test pressure: 200N | ||
Repeated bending Test | IEC 60794-1-2-E6 (GB/T 7424.2-E6) | After testing: no visible residual accessory attenuation of the fiber.No visually visible cracking of the sheath | Bending radius = 20 times the diameter of the micro cable | ||
Load = 15N | |||||
Bending times: 25 | |||||
Torsion test | IEC 60794-1-2-E7 (GB/T 7424.2-E7) | After the test: no fiber breakage and no visually visible cracking of the sheath.After stress removal, no obvious residual additional attenuation | Turning angle: ±180º | ||
Load = 15N | |||||
Number of torsions: 5 | |||||
Winding test | IEC 60794-1-2-E11A (GB/T 7424.2-E11A) | After the test: no fiber breakage and no visually visible cracking of the sheath | Mandrel diameter = 20 times the diameter of the micro cable | ||
Number of tightly wound turns = 10 | |||||
Number of cycles = 5 | |||||
All the above results are tested at 1550nm wavelength |
Blowing Performance
Test Equipment | Typical air delivery lengths and pipe types suitable for air delivery | ||
Polimente: PRM-196 , PR140 etc.Air pressure: 13bar | Fiber Count | Microtube type 3.5/5.0mm | Microtube type 5.5/7.0mm |
2~12 | 800m | 1500m | |
14~24 | 500m | 1500m |
Environmental Characteristics
Items | Test Method | Indicators to be achieved by the test |
Temperature Performance | IEC 60794-1-2-F1 | Additional attenuation of fiber (1550nm) |
≤0.1 dB/km | ||
Water penetration performance | IEC 60794-1-2-F5B | 1m water height, 3m cable, test time 24 hoursNo water seepage from the other end of the micro cable |
Drip performance | IEC 60794-1-2-E14 | Microcables are maintained at an ambient temperature of 70°C for 24 hoursNo filler compound drops out of microcables |
Product detail pictures:
![Customized Sc-LC Duplex Patch Cord Factories –Mini Air-Blown 2~24 Core Super Mini Unitube Air Blown Fiber Optic Cable – FCJ OPTO detail pictures](https://cdn.bluenginer.com/VSQegh4bgNNskpae/upload/image/products/Mini-air-blown-cable-2.jpg)
![Customized Sc-LC Duplex Patch Cord Factories –Mini Air-Blown 2~24 Core Super Mini Unitube Air Blown Fiber Optic Cable – FCJ OPTO detail pictures](https://cdn.bluenginer.com/VSQegh4bgNNskpae/upload/image/products/Mini-air-blown-cable-1.jpg)
Related Product Guide:
To create far more benefit for customers is our company philosophy; customer growing is our working chase for Customized Sc-LC Duplex Patch Cord Factories –Mini Air-Blown 2~24 Core Super Mini Unitube Air Blown Fiber Optic Cable – FCJ OPTO, The product will supply to all over the world, such as: Maldives, Korea, Amsterdam, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We've been able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and items. For anyone who is interested in our company and products, be sure to make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are about to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please genuinely feel no cost to speak to us for enterprise. nd we believe we have been gonna share the most effective trading practical experience with all our merchants.